Control unit FS850S

for standard use in ATEX and IECEx zones 1 and 21

Features
  • Explosion protection type pressurized enclosure: makes it possible to operate "non-Ex-approved" devices in hazardous areas of zones 1, 21, 2 and 22.
  • Compact system: Installation directly in the Ex area or in the Ex p-enclosure
  • Patented regulation of the internal housing pressure (patent DE 0004418158)
  • First system with proportional working pressure and flow sensors
  • Two valve or proportional valve technology for continuous purging mode prevents overloading and risk of bursting of the Ex p-enclosure in the event of faults at the outlet openings
Control unit FS850S
. . .
Mains:

230 V AC
110 - 120 V AC
24 V DC
 

.0
.2
.6
 
Orifice plate:

4 mm, Range 0,5 ...1,1 m 3 /h
6 mm, Range 1,1...2,7 m 3 /h
10mm, Range 2,5 ...6,5 m 3 /h
14 mm, Bereich 6 ...11 m 3 /h
18 mm, Bereich 9 ...15 m 3 /h


.0
.2
.4
.6
.8
 
Alarm contact:

Terminal 21, 22 as alarm contact


.1

Further voltages and pressure ranges on demand